Selected References

The following citations are the selected references about Microvolt T-Wave Alternans. For a complete bibliography, click here to download the PDF (844K).

Costantini O, et al. Patients With a Nonischemic Cardiomyopathy and a Negative T-Wave Alternans Stress Test Are at a Low Risk of Death. AHA 2004 Oral Presentation.

Daniel M. Bloomfield; Richard C. Steinman; Pearila B. Namerow; Michael Parides; Jorge Davidenko; Elizabeth S. Kaufman; Timothy Shinn; Anne Curtis; John Fontaine, Douglas Holmes; Andrea Russo; Chuen Tang; J. Thomas Bigger. Microvolt T-Wave Alternans Distinguishes Between Patients Likely and Patients Not Likely to Benefit From Implanted Cardiac Defibrillator Therapy: A Solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II Conundrum. Circulation. 2004; 110:1885-89.

Alfred Buxton, Michael O. Sweeney, Elaine Hogan Miller, Marry Otterness, Mark Wathen, Alice Stark. QRS Duration Does not Predict Occurrence of Ventricular Tachyarrhythmias in Primary Prevention Patients With Implantable Cardioverter Defibrillators. ACC 2004, Poster Presentation.

Walker ML, Rosenbaum DS. Repolarization alternans: implications for the mechanism and prevention of sudden cardiac death. Cardiovasc Res. 2003;57:599-614.

Hohnloser SH, Ikeda T, Bloomfield DM, Dabbous OH, Cohen RJ. T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation. The Lancet. 2003;362:125-126.

Hohnloser SH, Klingenheben T, Bloomfield D, Dabbous O, Cohen RJ. Usefulness of microvolt T-wave alternans for prediction of ventricular tachyarrhythmic events in patients with dilated cardiomyopathy: results from a prospective observational study. J Am Coll Cardiol. 2003;41:2220-4.

Gold MR, Spencer W. T wave alternans for ventricular arrhythmia risk stratification. Curr Opin Cardiol. 2003;18:1-5.

Bloomfield DM, Magnano AR, Parides MK. Comparison of T-wave alternans testing during treadmill and bicycle exercise in patients with congestive heart failure. Am J Cardiol. 2003;91:1493-7, A8.

Klingenheben T, Hohnloser SH. Clinical value of T-wave alternans assessment. Card Electrophysiol Rev. 2002;6:323-8.

Ikeda T, Kato T, Ozawa Y, Kasamaki Y, Ohnishi Y, Watanabe J, Shimizu H, Tanno K, Saito H. Usefulness of T-Wave Alternans for Effective Prophylactic Therapy in Patients with Prior Myocardial Infarction and Reduced Left Ventricular Ejection Fraction. Circulation. 2002;II:372 (abstract).

Ikeda T, Saito H, Tanno K, Shimizu H, Watanabe J, Ohnishi Y, Kasamaki Y, Ozawa Y. T-wave alternans as a predictor for sudden cardiac death after myocardial infarction. Am J Cardiol. 2002;89:79-82.

Klingenheben T, Cohen RJ, Bloomfield DM, Hohnloser S. Microvolt T-wave alternans predicts ventricular tachyarrhythmic events in non-ischemic dilated cardiomyopathy patients. Circulation. 2001;104 (suppl II):783 (abstract).

Klingenheben T, Zabel M, D'Agostino RB, Cohen RJ, Hohnloser SH. Predictive value of T-wave alternans for arrhythmic events in patients with congestive heart failure. Lancet. 2000;356:651-2.

Gold MR, Bloomfield DM, Anderson JM, El-Sherif N, Wilber D, Groh WJ, Estes NA, 3rd, Kaufman ES, Greenberg ML, Rosenbaum DS. A Comparison of T-Wave Alternans, Signal Averaged Electrocardiography and Programmed Ventricular Stimulation for Arrhythmia Risk Stratification. J Am Coll Cardiol. 2000;36:2247-53.